Overheating Analysis

Overheating is becoming a significant issue in new homes.

Studies by The Good Homes Alliance and the Zero Carbon Hub have shown that ever warmer, more airtight homes are posing serious risks to health and in some extreme cases, causing fatalities.

Overheating Analysis can predict risks, inform designers and developers, and improve the indoor environment for occupants.

Overheating AnalysisThe continual drive to deal with climate change has meant we are building warmer and warmer homes in winter.

But the effects of inadequate ventilation, high solar gains and increased air tightness means those same homes respond poorly through the summer months.

How Do We Perform Overheating Analysis?

Overheating analysis is typically performed using Dynamic Simulation Modelling (DSM) software which can analyses the occupied spaces and assess performance against criteria set by CIBSE (Chartered Institute of Building Services Engineers).

There are several instances where overheating analysis may be required:

  • To provide thermal comfort credits within a BREEAM Assessment
  • To achieve industry standards for thermal comfort i.e healthcare and education
  • Where designers want to reduce risk of overheating
  • To design-out overheating risks in dwellings identified by SAP Calculations
  • As requested as part of the planning application

Some dwellings in particular carry a higher overheating risk – for example, highly glazed south facing, single aspect apartments with limited cross ventilation. Planning officers may identify such dwellings as high risk and request a report within a Sustainability Statement or Energy Statement.

Overheating Analysis against CIBSE TM52Overheating Analysis

CIBSE TM52 (The Limits of Thermal Comfort:Avoiding Overheating in European Buildings 2013) is a Technical Memorandum (TM) to assist with assessing overheating in buildings.

TM52 outlines three criteria – a room or building that fails any two of the following three criteria is classed as overheating:

  • The number of hours that the operative temperature can exceed the threshold comfort temperature
  • The severity of overheating within one day – this is function of both temperature rise and it’s duration
  • An absolute maximum daily temperature for a room, beyond which the level of overheating is acceptable

Overheating Analysis1More detailed information about using simulation to predict the danger of overheating is available in CIBSE Guide A. CIBSE KS16: How to manage overheating in buildings.

In order to carry out simulations, a DSM package will be used – typically by an accredited Low Carbon Consultant and a report compiled.

Can We Help with Overheating Analysis On Your Project?

Just give us a call on 01202 280062 or send us your enquiry - we’ll get straight back to you.

facebook
"Very many thanks to all of you at Build Energy for a great service. Right now it can be really tough to get much done in the building trade, but you guys are the exception. Initial scoping discussions with Pete were really helpful, the quote arrived as promised in no more than an hour, and the work was completed within the agreed timescale of 5 working days from order, without any chasing. As the work was progressing Cam called me to discuss the assumptions he was making for the SAP calculations, and we arrived on a final assessment I have been able to discuss. Cam was even able to make a few final corrections almost by return. Thank you guys ... I would not hesitate to recommend you in future."