Search

(Type your query in the field above and press enter to search)

The TPER – what it is and how will it affect your project?

21 Jun 2021 at 11:42 AM

The Target Primary Energy Rating (TPER for short)

The TPER joins the CO2 based emissions target (DER/TER) within Part L of the Building Regulations, as the primary method of rating a buildings performance. This is assessed within SAP Calculations for new homes, and in non domestic buildings within SBEM calculations.

New buildings are assessed against 3 criteria:

  • TPER in kWhPE/m² – Primary Energy Rating. This is an indicator of energy use which is influenced by both fabric and fuel
  • TER in kgCO2/m²/year – Target Energy Rating. This is the old carbon target and is influenced by both fabric and fuel
  • TFEE in kWh/m²/year – Target Fabric Energy Efficiency. This is the existing target influenced by fabric only, and only applicable to new homes.

What is a TPER?

The PER

The TPER has been designed to give a fuller picture of a building’s performance and move the regs towards promoting lower energy demand buildings first and foremost.

It takes into account the fuel sources for heating and the environmental impact each fuel generation method has, for instance harvesting of biofuels, transportation of minerals and efficiency of power plants.

The Primary Energy Rating is generated by giving each form of fuel a Primary Energy Factor, applying this to the building’s energy demand. Where Renewables are used, these will be subtracted from the final energy demand before the TPER is calculated. Below are a few examples of how this may look for a typical dwelling:

Dwelling A

  • 90% efficient gas boiler
  • Heating demand of 10,000 kWh
  • Primary Energy factor of gas is 1.13 kWh/kWh

(10,000 kWh / 0.90 efficiency) multiplied by 1.13 PE factor = 12,556 kWh demand

Dwelling B

  • 300% efficient electric heat pump
  • Heating demand of 10,000 kWh
  • Primary Energy factor of electricity is 1.501 kWh/kWh

(10,000 kWh / 3.00 efficiency) multiplied by 1.501 PE factor = 5,003 kWh demand

Dwelling C

  • 100% efficient electric panel heaters
  • Heating demand of 10,000 kWh
  • Primary Energy factor of electricity is 1.501 kWh/kWh

(10,000 kWh / 1.00 efficiency) multiplied by 1.501 PE factor = 15,010 kWh demand

Dwelling D

  • 100% efficient electric panel heaters
  • Heating demand of 10,000 kWh
  • Primary Energy factor of electricity is 1.501 kWh/kWh

Addition of PV producing 2,500 kWh of electricity (1,500 kWh used within the dwelling, 1,000 kWh exported to the grid)

(10,000 kWh – 1,500 kWh / 1.00 efficiency) multiplied by 1.501 PE factor) minus (1,000 kWh x 0.501 PE factor to grid) = 12,759 kWh minus 501 kWh = 12,258 kWh demand

 

How will the TPER affect my projects?Primary Energy Rating (PER)

Taking this all into account, you may be wondering how this will affect your upcoming projects. The main points we can take away are:

  • The TPER is a realistic view of all of the energy required to run a home – not just the mains fuel we think is needed
  • The energy demand of a property needs to be counteracted with a high efficiency system
  • The TPER is not a measure of heat loss but the total energy demand of a property
  • The efficiency of the heating system being used is a decisive factor in determining the energy demand of a home (see examples above)
  • A combination of exceeding the target CO2 emission rate, target fabric energy efficiency and the target primary energy rating is needed to comply with Part L
  • It’s more important than ever to build efficiently and use renewable energy sources such as heat pumps and PV.

As always Build Energy will be here to guide you through the new regulations and support you in delivering the best solution for your projects.

Would you like to discuss your project?